Free Backflow Tester Practice Test 2026

200 backflow tester questions and four 50-question practice tests. Free to start, no account needed.

Try one now

Pick an answer

How many feet of water column equal 1 psi?

The Backflow Tester exam at a glance

Water suppliers and states require backflow prevention assemblies, such as reduced pressure principle assemblies, double checks and pressure vacuum breakers, to be tested by a certified backflow tester. ASSE International certifies testers under its 5110 standard: a candidate completes a tester course built on ASSE's 14 instructional objectives, then sits a written exam and a practical exam on real assemblies. ASSE's written exam instructions allow 2 hours, closed book with no notes or references, a calculator for math questions, one correct or best answer per question, grading by ASSE, and a passing score of 70% or better. ASSE does not publish the number of questions. California's State Water Resources Control Board recognized ASSE 5110 in June 2025. Many programs accept other certifications too, such as ABPA's, so check which your water supplier or state accepts.

Tigertest has 200 Backflow Tester practice questions with explanations, free to start with no account required.

Written exam time
2 hours
Book rule
Closed book; calculator allowed
Passing score
70% or better
Practical exam
Yes, field tests on real assemblies
Graded by
ASSE International
Covers
Cross-connections, hydraulics, assemblies, test kits, test procedures, troubleshooting, safety

Updated by the Tigertest team. Practice questions follow ASSE's tester course objectives and written exam instructions, checked November 2026. Exam rules change, so confirm current details with ASSE backflow instructor guide.

How It Works

Train by Topic

Five training sets: cross-connections and hydraulics; programs and tester duties; assemblies and installation; test kits and field tests; and troubleshooting and safety. Questions you miss come back until you have mastered them.

50-Question Practice Tests

Four practice tests of 50 questions, each with ASSE's 70% passing line. No question appears in more than one test, and every answer comes with a short explanation.

Built on ASSE's Tester Course Objectives

ASSE lists 14 course objectives for testers but publishes no weights. Tigertest splits each 50-question test across seven topics: 6 cross-connections, 7 programs, 7 hydraulics, 10 assemblies, 4 test kits, 10 field test procedures and 6 troubleshooting and safety.

Cross-Connections & Drinking Water Rules12%
Programs, Records & Tester Duties14%
Hydraulics & Pressure14%
Backflow Assemblies & Installation20%
Test Kits & Gauges8%
Field Test Procedures20%
Troubleshooting & Safety12%
Tigertest mascot

Help Make Tigertest Better

Have an idea, a topic you'd like covered, or a question that could be clearer? We read every message and use it to improve every test.

Share Feedback

How to Pass the Backflow Tester Exam

1. Match the device to the hazard

Know which devices stop backsiphonage only (the vacuum breakers and the barometric loop) and which also stop backpressure (the air gap, double checks and RPs), and which hazards call for an RP rather than a double check.

2. Learn the pass numbers cold

RP first check at least 5 psid, relief valve opening at 2 psid or more, double check and PVB checks at 1 psid, PVB air inlet at 1 psid. Know which test cocks each reading is taken between.

3. Read failures like a flow chart

A relief valve that discharges when the #2 shutoff closes, a gauge that rises, a relief that drips too early or never: each points to one part. Learn what each symptom means and when a no-flow condition must come first.

4. Do the pressure math

0.433 psi per foot of water, 2.31 feet per psi, 14.7 psi of atmosphere. Practice converting between psig and psia and working out head. Then take the 50-question tests and aim well above 70%, around 85%, before your exam.

Backflow Tester Frequently Asked Questions

What is the backflow tester certification exam?

Water suppliers and states require backflow prevention assemblies to be tested by a certified tester. ASSE International certifies testers under its 5110 standard: candidates take a tester course, then a written exam and a practical exam on real assemblies. California's State Water Board recognized ASSE 5110 in June 2025. Many programs also accept other certifications, such as ABPA's, so check which ones your water supplier or state accepts.

How is the ASSE backflow tester written exam run?

ASSE's written exam instructions allow 2 hours, closed book, with no notes or reference material, though a calculator may be used for math questions. Each question has one correct or best answer, ASSE grades the exam, and 70% or better passes. ASSE does not publish the number of questions. A separate practical exam checks that you can test the assemblies.

What does the backflow tester exam cover?

ASSE's tester course objectives cover cross-connections and their history, drinking water regulations, cross-connection programs and tester duties, hydraulics such as backsiphonage, backpressure and the pressure scales, the parts and installation of air gaps, vacuum breakers, double checks, RPs and detector assemblies, test kits, field test procedures, troubleshooting, records and safety.

What are the pass readings for an RP, double check and PVB?

Under ASSE's field test flow charts, an RP's first check must hold at least 5 psid and its relief valve must open at 2 psid or more, with the second check tight under backpressure. Each check on a double check must hold more than 1 psid. A PVB's check must hold at least 1 psid and its air inlet must open at 1 psid or more. Local programs may add their own steps.

Are these the real ASSE questions?

No. Every question is original, written by Tigertest from ASSE's published course objectives and field test flow charts, the US EPA Cross-Connection Control Manual and federal regulations. Tigertest is not affiliated with ASSE International, IAPMO or the American Backflow Prevention Association, and no exam or course question was used.

I teach a backflow tester certification course. Can my students use Tigertest?

Yes, for free. Make a class at tigertest.io/teach, post one link, and students join with just their name. You see who practiced, their test scores and the topics your class misses most.

Backflow Tester sample questions and answers

6 of the 200 practice questions, one from each topic, with the answer explained.

  1. 1. Reduced pressure principle assemblies come in sizes from 3/4 inch through:

    • A.24 inches
    • B.10 inches
    • C.2 inches
    • D.4 inches

    Answer: B. EPA lists RPs from 3/4-inch through 10-inch, with different body styles for the smaller and larger sizes.

  2. 2. Two open tanks are joined by a full pipe looping over a wall, one tank higher. Water will:

    • A.Stay still in both tanks
    • B.Flow to the higher tank
    • C.Drain out of both tanks
    • D.Siphon to the lower tank

    Answer: D. Both surfaces are at atmospheric pressure, but at every level the pressure is lower in the leg over the lower tank, so EPA's U-tube flows from the higher tank to the lower one.

  3. 3. EPA warns that symptoms of drinking water with high chromium include:

    • A.Nausea and a burning throat
    • B.Blistered skin and hair loss
    • C.Blurred vision and fever
    • D.Joint pain and rashes

    Answer: A. In the school dichromate case, physicians advised the symptoms would be nausea, diarrhea and burning of the mouth and throat.

  4. 4. A gauge needle drifts while the hoses are connected and the valves closed. First suspect:

    • A.A fouled meter
    • B.Low static line pressure
    • C.Air in the hoses
    • D.A failed air gap

    Answer: C. An unsteady needle usually means air remains in a hose; bleed the high, then the low hose, and read again.

  5. 5. A city keeps a list of certified private testers. Per EPA's model program, who pays for the test?

    • A.City water department
    • B.Tester's own employer
    • C.Building or property owner
    • D.State health agency

    Answer: C. The model program says all charges for these tests are paid by the owner of the building or property.

  6. 6. A repaired RP is ready to return to service. What must the tester do last?

    • A.Open #2 shutoff, drain kit
    • B.Leave #2 shutoff closed
    • C.Plug all four test cocks
    • D.Disable the relief valve

    Answer: A. Restore the assembly to its pre-test condition: open #2 shutoff, remove the kit and drain it.

Every test on Tigertest is free to start, with no account needed.

See all 500 practice tests

Ready for Your Backflow Tester Exam?

Start for free. No account required. 200 questions on assemblies, test procedures and troubleshooting.

Start practicing