Free EPA 608 Practice Test 2026

Core, Type I, II and III. 200 questions at the real 72% pass line. Free to start, no account needed.

Try one now

Pick an answer

Which refrigerant has an ozone depletion potential of zero but a relatively high global warming potential?

The EPA 608 exam at a glance

The EPA Section 608 exam has four sections (Core, Type I, Type II, Type III) of 25 multiple-choice questions each, and you need 18 correct (72%) on each section. Core plus one type earns that type; Core plus all three is Universal certification, 100 questions in total. Type II and III are always proctored and closed book.

Tigertest has 200 EPA 608 practice questions with explanations, free to start with no account required.

Questions
25 per section, 100 for Universal
Passing score
18 of 25 (72%) per section
Sections
Core, Type I, Type II, Type III
Given by
EPA-approved certifying organizations

Updated by the Tigertest team. Practice questions follow EPA Section 608 technician certification requirements. Exam rules change, so confirm current details with US EPA.

How It Works

One Set per Section

Taking Type II only? Train Core and Type II. Each set is one section of the real exam, and questions you miss come back until you have mastered them.

Mixed Practice Tests

Four 50-question tests across all four sections at the real 72 percent pass line. Built for Universal candidates who want everything at once.

The Four Sections of the EPA 608 Exam

Every section is 25 questions, 18 to pass. Core is on every certification; the type sections add the equipment you will service.

CoreOzone, regulations, recovery, safety, shipping 路 required for everyone
72 questions
Type I: Small Appliances5 lb or less: refrigerators, window units, vending machines
40 questions
Type II: High-PressureSplit systems, packaged units, commercial refrigeration
52 questions
Type III: Low-PressureCentrifugal chillers running in a vacuum
36 questions
Tigertest mascot

Help Make Tigertest Better

Have an idea, a topic you'd like covered, or a question that could be clearer? We read every message and use it to improve every test.

Share Feedback

How to Pass the EPA 608 Exam

1. Decide which certification you need

Type I for small appliances, Type II for high-pressure systems like split ACs and commercial refrigeration, Type III for low-pressure chillers. Most HVAC technicians go straight for Universal, which is Core plus all three types.

2. Learn the numbers

Recovery levels by appliance size and type, 500 microns, 80 percent cylinder fill, the 30, 20 and 10 percent leak rates with 30 days to repair, 125 F cylinder limit, the 1992 and 1995 venting dates, the 2020 R-22 phase-out and the AIM Act HFC rules. The Core set drills them all.

3. Know what appears on every section

Safety, shipping, refrigerant identification and the regulations show up in every section, not just Core. If you only study the type section, you will lose those points.

4. Drill your weak areas

Tigertest tracks your accuracy by section. After each mixed test, go back to the set you missed most and retake until you clear 72 percent with room to spare.

EPA 608 Frequently Asked Questions

How many questions are on the EPA 608 exam?

Each section has 25 multiple-choice questions and you need 18 correct, 72 percent. Core is required for any certification. Core plus one type gives that type; Core plus all three gives Universal, 100 questions in total.

What is the difference between Type I, II and III?

Type I covers small appliances with 5 pounds or less of refrigerant, such as refrigerators and window units. Type II covers high-pressure appliances such as split systems and commercial refrigeration. Type III covers low-pressure appliances, mainly centrifugal chillers. Universal covers all three.

Is the EPA 608 exam open book?

Some providers offer Type I as an open-book online test, but Type II, Type III and Universal must be taken proctored and closed book. Check with your testing organization, since the rules depend on the provider.

Is the Tigertest EPA 608 practice test free?

Yes. Start for free with no account required: every training set and practice test is free except the final one of each, which is part of Tigertest Premium (one payment, no subscription). Create a free account if you want your progress saved across devices.

I teach EPA 608 certification classes. Can my students use Tigertest?

Yes, for free. Make a class at tigertest.io/teach, post one link, and students join with just their name. You see who practiced, their test scores and the topics your class misses most.

EPA 608 sample questions and answers

4 of the 200 practice questions, one from each topic, with the answer explained.

  1. 1. A technician is shipping a full recovery cylinder to a reclaimer. What must the cylinder's labeling show?

    • A.The reclaimer's AHRI 700 test results
    • B.Refrigerant name and DOT classification
    • C.The technician's certification card number
    • D.The leak rate of the source system

    Answer: B. DOT requires the cylinder to be labeled with its contents (a proper shipping name such as "Refrigerant gas, n.o.s." for a mixture) and its hazard class tag, matching the shipping papers. Check with the reclaimer for any added paperwork it requires.

  2. 2. Under the 2016 Section 608 update, the sales restriction to certified technicians was extended to HFC refrigerants such as R-134a on:

    • A.November 15, 1993
    • B.January 1, 2010
    • C.July 1, 2022
    • D.January 1, 2018

    Answer: D. Starting January 1, 2018, the sale of HFC refrigerants such as R-134a was restricted to certified technicians, with an exception for small cans of MVAC refrigerant (40 CFR 82.154).

  3. 3. A technician will recover R-454B from a newly installed split system. What precaution is specific to this A2L refrigerant?

    • A.Use recovery equipment rated for A2Ls
    • B.Recover into a disposable cylinder
    • C.Pressurize it with oxygen afterward
    • D.Vent the charge outdoors only

    Answer: A. A2L refrigerants such as R-32 and R-454B are lower toxicity and mildly flammable, so recovery machines, tools and cylinders must be rated for A2L use and ignition sources eliminated.

  4. 4. On an open-drive low-pressure chiller, which component is a common source of refrigerant leaks?

    • A.The cooling tower fill media
    • B.The hermetic motor terminals
    • C.The compressor shaft seal
    • D.The chilled water pump seal

    Answer: C. Open-drive compressors have a shaft passing through the housing, and the shaft seal is a frequent leak point; hermetic designs avoid this seal.

EPA 608 practice questions by topic

Ten questions on each area of the exam, with the answers explained.

馃嚜馃嚫 Espa帽ol

Every test on Tigertest is free to start, with no account needed.

See all 556 practice tests

Ready to Go Universal?

Start for free. No account required. 200 questions across all four sections.

Start practicing