Free G3 Gas Technician Practice Test 2026
200 TSSA G3 questions and four 50-question practice tests. Free to start, no account needed.
Try one now
Pick an answer
Which fire class covers a burning natural gas leak?
The G3 Gas Technician exam at a glance
The Gas Technician 3 (G.3) is Ontario's entry-level gas technician certificate, issued by the Technical Standards and Safety Authority (TSSA) under Ontario Regulation 215/01. Candidates complete a TSSA-accredited program of curriculum modules 1 to 9 (a suggested 180 hours) or the challenge route, then write a multiple-choice TSSA certification exam with the permitted references (the Technical Standards and Safety Act, the fuels regulations and code adoption documents, CSA B149.1 and B149.2) and pass a practical evaluation. TSSA requires 75% on the exam, in each module and on the practical. A G.3 works under the general supervision of a G.1, G.2 or DA holder on listed tasks once they are signed off, and under direct supervision for anything else in that holder's scope.
Tigertest has 200 G3 Gas Technician practice questions with explanations, free to start with no account required.
- Run by
- TSSA (Ontario)
- Certificate
- Gas Technician 3 (G.3), O. Reg. 215/01
- Training
- Curriculum modules 1 to 9, suggested 180 hours
- Pass mark
- 75% on the exam, each module and the practical
- Format
- Multiple choice, open book with permitted references
- Question count
- Not published (TSSA exams run 50 to 165)
- Gas code
- CSA B149.1-25 with Ontario amendments, from June 1, 2026
- Failed three times
- An accredited program before another attempt
Updated by the Tigertest team. Practice questions follow TSSA's Gas Technician/Oil Burner Technician Policies and Procedures (March 2025), TSSA Certification Examination Preparation Guide (March 2026), O. Reg. 215/01 and the Gaseous Fuels CAD amendment FS-279-26, checked November 2026. Exam rules change, so confirm current details with TSSA Gas Technician/Oil Burner Technician Policies and Procedures.
How It Works
Train by Module
Four training sets that follow the G.3 curriculum: safety and tools; gas properties, codes and acts; electricity, drawings and customers; and piping, tubing and appliances. Questions you miss come back until you have mastered them.
Full Practice Tests
Four practice tests of 50 questions that mix all nine modules, with the same 75% pass line TSSA uses. No question appears in more than one test, and every explanation names the regulation, Ontario amendment or principle behind the answer.
Built on the G.3 Modules and Ontario Law
TSSA's G.3 program is curriculum modules 1 to 9. The legal questions come from Ontario Regulation 212/01, Ontario Regulation 215/01 and TSSA's public Ontario amendments to CSA B149.1-25. TSSA publishes no topic weights for the G3 exam, so each practice test spreads its 50 questions as below.

Help Make Tigertest Better
Have an idea, a topic you'd like covered, or a question that could be clearer? We read every message and use it to improve every test.
Share FeedbackHow to Pass Your G3 Exam
1. Know what a G3 may and may not do
Section 22 of O. Reg. 215/01 is short: learn the four general-supervision tasks, the 2-1/2 inch piping limit, the difference between general and direct supervision, and the one thing a G3 never does under general supervision, the first activation of a new appliance.
2. Learn the unacceptable condition steps
O. Reg. 212/01 sets out what to do when an appliance is an immediate hazard: shut it off, tell the distributor and the user, tag it, and send written notice within 14 days. Know who may remove a tag and the 90-day limit when there is no immediate hazard.
3. Use your code book like a reference
The exam is open book with the permitted references, so practise finding Ontario's amendments quickly: burial depth, valve placement, the pressure test tag, boiler checks and chimney liner deadlines.
4. Drill the arithmetic
Ohm's law, flow from input and heating value, inches of water column to psi, and combustion air are quick marks once the steps are automatic. Aim for 75% or better on every practice test here before you book your exam.
G3 Gas Technician Frequently Asked Questions
What is the G3 gas technician certificate?
The Gas Technician 3 (G.3) is Ontario's entry-level gas certificate under Ontario Regulation 215/01, issued by the Technical Standards and Safety Authority (TSSA). Working under the general supervision of a G.1, G.2 or DA holder, and once those skills are signed off, a G.3 may install, test and purge gas piping under 2-1/2 inches up to the appliance control valve, reactivate existing appliances, clean them and service vent connectors. A G.3 may not do the first activation of a new appliance.
What score do I need to pass the TSSA G3 exam?
TSSA's Gas Technician policies require 75% on the TSSA certification exam, 75% in each curriculum module and 75% on the practical evaluation. The exam is multiple choice, and candidates may bring the permitted references: the Technical Standards and Safety Act, the fuels regulations and code adoption documents, CSA B149.1 and CSA B149.2. TSSA does not publish the G3 question count; its preparation guide says exams run from 50 to 165 questions and up to three and a half hours, depending on the certificate.
What does the G3 training cover?
TSSA's G.3 program is curriculum modules 1 to 9, a suggested 180 hours: protecting yourself and others; fasteners, hand and power tools; properties and safe handling of propane and natural gas; installation codes, acts and regulations; an introduction to electricity; manuals, specifications, schematics, drawings and graphs; customer relations; piping and tubing systems; and gas appliances.
Which edition of the gas code applies in Ontario?
TSSA's Gaseous Fuels Code Adoption Document amendment FS-279-26 adopts CSA B149.1-25 with Ontario amendments, effective June 1, 2026. The amendments add Ontario rules such as the 15 inch burial depth, the pressure test tag, the heating-season check of natural draft boilers and the chimney liner deadlines. Where the amendment and B149.1 conflict, the amendment prevails.
Are these real TSSA G3 exam questions?
No. TSSA does not publish practice exams, and every question here is original, written by Tigertest from the regulations, TSSA's public code adoption document and public safety references. CSA code text and the paid training modules are not reproduced. It is practice, not affiliated with TSSA or CSA Group, and it does not replace an accredited G3 program.
I teach a gas technician (G3) class. Can my students use Tigertest?
Yes, for free. Make a class at tigertest.io/teach, post one link, and students join with just their name. You see who practiced, their test scores and the topics your class misses most.
G3 Gas Technician sample questions and answers
6 of the 200 practice questions, one from each topic, with the answer explained.
1. When checking a furnace, its temperature rise must fall within:
- A.The thermostat setting
- B.The rating plate range
- C.5 to 10 F always
- D.Any value under 100 F
Answer: B. The rating plate gives the allowed rise between return and supply air. Too high stresses the heat exchanger; too low can cause condensation.
2. A boiler inspection tag from that heating-season check expires on:
- A.December 31 that year
- B.One year from the date
- C.October 15 the next fall
- D.May 1 after the check
Answer: D. The Ontario amendment sets the tag to expire on May 1 after the check; a check done between May 1 and October 14 counts for the next heating season.
3. A customer asks you to bypass a safety switch so the furnace keeps running. What do you do?
- A.Refuse and explain why
- B.Bypass it for one night
- C.Bypass it if they sign
- D.Remove the switch
Answer: A. Safety controls stop unsafe operation; defeating them can cause fire or CO poisoning, and no customer request makes that legal or safe. Explain the risk and repair the fault.
4. A 1,800 W portable heater runs on 120 V. What current does it draw?
- A.0.07 A
- B.1.5 A
- C.15 A
- D.150 A
Answer: C. I = P / E = 1,800 / 120 = 15 A. 0.07 A divides the wrong way (120 / 1,800), and 1.5 A and 150 A misplace the decimal.
5. Which condition must be present, along with fuel and heat, for gas to burn?
- A.Carbon dioxide
- B.Water vapour
- C.Oxygen
- D.Nitrogen
Answer: C. The fire triangle is fuel, heat and oxygen. Remove any one, such as shutting off the gas, and the fire stops.
6. A gas line is sized for 1,000 Btu/ft3 gas. A 120,000 Btu/h load needs about:
- A.120 cfh
- B.1,200 cfh
- C.12 cfh
- D.48 cfh
Answer: A. Cubic feet per hour = input / heating value = 120,000 / 1,000 = 120 cfh. 48 cfh uses propane's 2,500 Btu/ft3.
Related practice tests
Every test on Tigertest is free to start, with no account needed.
- Canadian Firearms Safety Course Practice TestRCMP Canadian Firearms Program · non-restricted PAL
- Red Seal Electrician Practice TestRed Seal interprovincial exam · provincial apprenticeship authorities
- WHMIS Practice TestHealth Canada HPR · WHMIS 2015 workplace training
- Smart Serve Ontario Practice TestSmart Serve Ontario · AGCO Board-approved responsible service training, Full Course final test
- ProServe Practice TestAlberta Gaming, Liquor and Cannabis (AGLC) · ProServe Liquor Staff Training
- BC Security Guard Practice TestJustice Institute of BC for the BC Registrar of Security Services · Basic Security Training (BST) exam
Ready for Your G3 Exam?
Start for free. No account required. 200 questions on gas safety, Ontario law, piping, electricity and appliances.
Start practicing