Free Red Seal Refrigeration Practice Test 2026
200 Refrigeration and Air Conditioning Mechanic questions with the real 70% pass mark. Free to start, no account needed.
Try one now
Pick an answer
What colour is a refillable recovery cylinder in Canada?
The Red Seal Refrigeration exam at a glance
The Red Seal Refrigeration and Air Conditioning Mechanic exam is the interprovincial certificate of qualification exam for the trade in Canada (trade code 313A in Ontario). It has 125 multiple-choice questions with four options each, a pass mark of 70%, and four hours to write it. Red Seal's exam breakdown spreads the questions over six Major Work Activities, led by maintenance and service (31 questions), installation (26) and commissioning (22). Red Seal says new exams on the 2024 standard are under development, so check with your apprenticeship authority which version you will write.
Tigertest has 200 Red Seal Refrigeration practice questions with explanations, free to start with no account required.
- Questions
- 125 multiple choice, 4 options each
- Time
- 4 hours
- Pass mark
- 70%
- Largest areas
- Maintenance and service 31, installation 26, commissioning 22
- Other areas
- Routine trade activities 20, planning installation 16, common occupational skills 10
- Standard
- Red Seal Occupational Standard for Refrigeration and Air Conditioning Mechanic
- Booked through
- Your provincial or territorial apprenticeship authority
Updated by the Tigertest team. Practice questions follow the Red Seal exam information page for Refrigeration and Air Conditioning Mechanic and the Red Seal Exam Preparation Guide, checked November 2026. Exam rules change, so confirm current details with Red Seal: Refrigeration and Air Conditioning Mechanic exam information.
How It Works
Train, Then Test
Five training sets by topic, from Safety, Tools & Trade Practices to Control Systems. Master a topic, then take a test. Questions you miss come back until you have mastered them.
Practice Tests
Four 50-question tests weighted like the Red Seal exam breakdown, with the same 70% pass mark and an explanation of the right answer on every question.
Built on the Red Seal Exam Breakdown
Red Seal publishes how many of the 125 questions come from each of the six Major Work Activities in the Occupational Standard for Refrigeration and Air Conditioning Mechanic, and the practice tests here keep that split in 50 questions. Maintenance and service carries the most weight, about a quarter of the exam, with installation and commissioning close behind. Instructors running a refrigeration apprenticeship class can assign Tigertest at tigertest.io/teach and see which work activities the class misses most.

Help Make Tigertest Better
Have an idea, a topic you'd like covered, or a question that could be clearer? We read every message and use it to improve every test.
Share FeedbackHow to Pass the Red Seal Refrigeration Exam
1. Read the system, not one gauge
Most troubleshooting questions give two or three readings. Learn what superheat, subcooling, suction and head pressure each do with an undercharge, an overcharge, a restriction, low airflow and a dirty condenser, so you can match a pattern instead of guessing from one number.
2. Know the procedures step by step
Brazing with a nitrogen purge, pressure testing with a regulated nitrogen cylinder, deep evacuation with a micron gauge and decay test, weighing in the charge and charging blends as liquid all come up as "what comes first" questions.
3. Learn controls and the refrigerant rules
Thermostat terminals, pressure controls, defrost, sensors and building automation are a large share of installation and service. Pair them with the federal halocarbon rules on releases, leak tests and recovery, and the ASHRAE 34 safety classes for A1, A2L and A3 refrigerants.
4. Fix your misses, then retest
Tigertest tracks your accuracy by topic. Aim for 80% or better on all four practice tests before you book, so you have room above the 70% line. After each test, drill the questions you missed and retrain your weakest topic.
Red Seal Refrigeration Exam Frequently Asked Questions
What is the pass mark for the Red Seal Refrigeration and Air Conditioning Mechanic exam?
You need 70 percent. The exam has 125 multiple-choice questions, each with four options and one correct answer, and the Red Seal exam preparation guide gives four hours to write it. A calculator is provided if you need one, and the formulas used on the exam are given to you at the sitting.
What does the Red Seal Refrigeration and Air Conditioning Mechanic exam cover?
Red Seal's exam breakdown spreads the 125 questions over six Major Work Activities: maintenance and service 31, installation 26, commissioning 22, routine trade activities such as brazing, leak testing, evacuation and refrigerant handling 20, planning installation and retrofits 16, and common occupational skills 10. The practice tests here keep those proportions in 50 questions.
Which standard is the exam based on?
Red Seal published a new Occupational Standard for the trade in 2024 and says new exams based on it are under development, while current exams were built on the previous standard. The exam breakdown on red-seal.ca already uses the new task numbering, and the two standards cover the same core work. Check with your apprenticeship authority which version you will write.
Is 313A the same as the Red Seal exam?
313A is the Ontario trade code for Refrigeration and Air Conditioning Systems Mechanic. Ontario candidates who pass the interprovincial exam earn the Red Seal endorsement, the same exam written across Canada. Eligibility, booking, fees and retake rules are set by each province or territory, so check with yours before you apply.
Are these the real Red Seal exam questions?
No. Red Seal exam questions are confidential. Every question here is written by Tigertest from the published exam breakdown, the Occupational Standard, the Federal Halocarbon Regulations and Environment and Climate Change Canada's code of practice, so it covers the same tasks without copying the exam. Tigertest is not affiliated with the Red Seal Program. Refrigerant handling certificates and rules also vary by province, so follow your provincial rules and the equipment maker's instructions.
I teach a refrigeration and air conditioning apprenticeship program. Can my students use Tigertest?
Yes, for free. Make a class at tigertest.io/teach, post one link, and students join with just their name. You see who practiced, their test scores and the topics your class misses most.
Red Seal Refrigeration sample questions and answers
6 of the 200 practice questions, one from each topic, with the answer explained.
1. When commissioning a ductless heat pump, why is heating mode also run, even in summer?
- A.Dries the indoor coil
- B.Tests the reversing valve
- C.Burns off factory oil
- D.Sets the refrigerant charge
Answer: B. Commissioning checks every mode the unit will use, including the reversing valve switching, so a fault is found before the heating season.
2. Why is a freeze stat installed across the face of a hydronic heating coil in an air handler?
- A.Controls supply air humidity
- B.Measures outdoor air flow
- C.Starts the economizer
- D.Stops it before freezing
Answer: D. A capillary freeze stat strung across the coil face senses cold spots and stops the fan or closes outdoor dampers before water in the coil can freeze.
3. Why is a calibrated reference used when checking a humidity sensor?
- A.They drift with age and contamination
- B.Humidity sensors cannot fail
- C.It sets the dew point
- D.It powers the sensor
Answer: A. Relative humidity sensors drift with age and contamination. A calibrated reference shows the offset so it can be corrected or the sensor replaced.
4. When a wall penetration is made for a line set, what keeps out weather and pests?
- A.A drain trap
- B.Wider wall bracket
- C.Sealed sleeve or cover
- D.Extra insulation on the line
Answer: C. Penetrations get a sleeve or line set cover sealed against the wall, which stops water, air leakage and insects.
5. After maintenance changes the setpoints of an integrated system, what should be done?
- A.Reset the controller to defaults
- B.Leave settings unrecorded
- C.Record the new settings
- D.Remove the old labels
Answer: C. Optimizing performance includes documenting what was changed, so the owner and the next mechanic know the current settings and why.
6. Why is the refrigerant charge recalculated when a split system's line set is longer than standard?
- A.Extra tubing holds more liquid
- B.Longer lines raise the voltage
- C.The oil changes type
- D.The compressor speeds up
Answer: A. Factory charges cover a set line length. Additional length holds more liquid in the liquid line, so the maker gives extra charge per metre.
Related practice tests
Every test on Tigertest is free to start, with no account needed.
- Red Seal Truck and Transport Mechanic Practice TestRed Seal interprovincial exam · Occupational Standard for Truck and Transport Mechanic
- Canadian Firearms Safety Course Practice TestRCMP Canadian Firearms Program · non-restricted PAL
- Red Seal Electrician Practice TestRed Seal interprovincial exam · provincial apprenticeship authorities
- Canada Drone Basic Exam Practice TestTransport Canada · Small Basic Exam, TP 15263 and CARs Part IX
- Canada Drone Advanced Exam Practice TestTransport Canada · Advanced Exam, TP 15263, CARs Part IX and Standard 922
- Canadian Amateur Radio Basic Practice TestISED · Amateur Radio Operator Certificate, Basic Qualification (RIC-3)
Ready to Earn Your Red Seal?
Start for free. No account required. 200 questions across all six Major Work Activities.
Start practicing